<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Health System Research</title>
<title_fa>مجله تحقیقات نظام سلامت</title_fa>
<short_title>J Health Syst Res</short_title>
<subject>Medical Sciences</subject>
<web_url>http://hsr.mui.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-2363</journal_id_issn>
<journal_id_issn_online>2322-5564</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.48305</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1390</year>
	<month>11</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2012</year>
	<month>2</month>
	<day>1</day>
</pubdate>
<volume>7</volume>
<number>6</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی و کنترل آلودگی صدای مولدهای دیزلی برق جوشکاری در کارگاه‌های ساختمان‌سازی شهر همدان</title_fa>
	<title></title>
	<subject_fa>آموزش بهداشت و ارتقاء سلامت </subject_fa>
	<subject>education health and promotion</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>مقدمه: مولدهای دیزلی که جهت تأمین برق مورد نیاز جوشکاری مورد استفاده قرار می&#8204;گیرند، می&#8204;توانند سبب آلودگی صوتی در محدوده کارگاه&#8204;های ساختمان&#8204;سازی شوند. مطالعه حاضر با هدف ارزیابی صدای این دستگاه&#8204;ها و ارایه راه&#8204;کار کنترلی مناسب در شهر همدان صورت پذیرفته است.&amp;nbsp; روش&#8204;ها: در این مطالعه توصیفی- تحلیلی و تجربی، تراز فشار صوت در فاصله یک متری و در 4 نقطه اطراف دستگاه&#8204;ها و در مجاورت معابر اندازه&#8204;گیری گردید و برای ایستگاه&#8204;های بالاتر از حد مجاز آنالیز فرکانس نیز صورت گرفت. سپس با استفاده از پرسش&#8204;نامه طراحی شده، آزار صوتی همسایگان مجاور کارگاه&#8204;ها مورد بررسی قرار گرفت. جهت کاهش تراز فشار صوت این مولدها متناسب با اهداف مطالعه و محاسبات طراحی از انباره مناسب موجود در بازار استفاده گردید و داده&#8204;ها با استفاده از SPSS نسخه 13 مورد تحلیل قرار گرفت. یافته&#8204;ها: میانگین و انحراف معیار SPL در اطراف دستگاه&#8204;ها (A) dB2/2 &amp;plusmn; 1/97 و میانگین و انحراف معیار آن در معابر اطراف آن برابر با (A) dB4/7 &amp;plusmn; 0/74 بوده، که هر 2 مورد بالاتر از حد مجاز تعیین شده بود. 7/60 درصد از همسایگان آزار صوتی ناشی از صدای فعالیت&#8204;ها را بالا می&#8204;دانستند. با استفاده از انباره انتخاب شده، کاهش تراز فشار صوتی در مدل بنز برابر با 4/24 دسی&#8204;بل در فرکانس 63 هرتز و 11 &#8204;دسی&#8204;بل در تراز فشار کلی صوت و در مدل رومانی به ترتیب 2/21 و 5/9 دسی&#8204;بل حاصل گردید. نتیجه&#8204;گیری: صدای اگزوز عامل اصلی صدای این دستگاه&#8204;ها است، که با انباره مناسب می&#8204;توان به کاهش تراز فشار صوت قابل قبولی در فرکانس اصلی دست یافت. &amp;nbsp; واژه&#8204;های کلیدی: کارگاه&#8204;های ساختمانی، مولدهای دیزلی، انباره صوتی، کنترل صدا، آزار صوتی</abstract_fa>
	<abstract>Background and Aims: Since using city power for welding process is not allowed, diesel generators are used as a power supply in construction industries. They could be introduced as a main source of noise pollution. The purposes of this study were to assess and control noise pollution produced by construction diesel generators in Hamadan, Iran.Methods: In this descriptive, cross-sectional study, sound pressure level (SPL) was measured in 4 points at a distance of 1 meter from a diesel generator. Frequency analysis was also conducted for stations with SPLs higher than the standard limit. The noise disturbance questionnaire was then used to investigate noise disturbance among neighbors. Appropriate mufflers were designed to reduce SPL based on the objectives of the study. Finally, data was analyzed by SPSS13.Findings: Our results showed that the mean values of SPL around the generators and on the nearby streets were 97.0 &amp;plusmn; 2.2 and 74.0 &amp;plusmn; 7.4 dB(A), respectively. &amp;nbsp;These values both exceeded the recommended levels. Overall, 60.7% of the neighbors were disturbed by the noise from construction activities. Using the designed muffler in the Benz model, SPL reduction at 63 Hz was 24.4 dB and total reduction was 11 dB. The corresponding values were 21.2 and 9.5 dB in the Romania model.Conclusion: Exhaust system was a main source of noise in diesel generators. Therefore, appropriate mufflers would reduce noise pollution.</abstract>
	<keyword_fa></keyword_fa>
	<keyword></keyword>
	<start_page>0</start_page>
	<end_page>0</end_page>
	<web_url>http://hsr.mui.ac.ir/browse.php?a_code=A-10-39-245&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name>رستم گلمحمدي</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رستم گلمحمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Associate Professor, Department of Professional Health Engineering, School of Health And Health Sciences Research Center, Hamadan University of Medical Sciences, Hamadan, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name>حيدر محمدي</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حیدر محمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>MSc Student, Department of Professional Health Engineering, School of Health, Hamadan University of Medical Sciences, Hamadan, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name>هادي بيات</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>هادی بیات</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>MSc Student, Department of Occupational Health Engineering, School of Public Health, Hamadan University of Medical Sciences, Hamedan, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name>عليرضا سلطانيان</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>علیرضا سلطانیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Department of Biostatistics, School of Health, Hamadan University of Medical Sciences, Hamadan, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
