<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Health System Research</title>
<title_fa>مجله تحقیقات نظام سلامت</title_fa>
<short_title>J Health Syst Res</short_title>
<subject>Medical Sciences</subject>
<web_url>http://hsr.mui.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2783-4093</journal_id_issn>
<journal_id_issn_online>2322-5564</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.48305</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1394</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2015</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<volume>11</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی تأثیر استفاده از سایلنسر جذبی در کاهش صدای فرکانس پایین فن محوری ایرانی</title_fa>
	<title>Investigation on use of Absorptive silencer in reduction Low-frequency noise Iranian axial fan</title>
	<subject_fa>آموزش بهداشت و ارتقاء سلامت </subject_fa>
	<subject>education health and promotion</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>مقدمه: سیستم&amp;lrm;های تهویه ازجمله مهم&amp;lrm;ترین منابع صدا در ساختمان&amp;lrm;ها هستند که از بخش&amp;lrm;های چون فن، کانال یا توزیع&#8204;کننده&amp;lrm;ها، توزیع و به محیط اطراف انتشار می&amp;lrm;یابند. فن&amp;lrm;های محوری در صنعت بسیار استفاده می&amp;lrm;شوند و سایلنسرها از جمله راه&#8204;های کنترل صدای فن ها محسوب می&amp;lrm;شوند. هدف از این مطالعه بررسی تأثیر استفاده از سایلنسر جذبی در کاهش صدای فرکانس پایین فن محوری ایرانی است.روش&#8204;ها: در این مطالعه از کانال گالوانیزه 6/. میلی&#8204;متر با ابعاد 30*30 سانتی متر مربع و فن محوری استفاده شد. سایلنسر جذبی نیز از جنس کانال به گونه&#8204;ای طراحی شد تا سطح مقطع کانال و سایلنسر پس از تعبیه جاذب در کانال باهم یکسان شود. سایلنسر جذبی به طول 50 سانتی&#8204;متر و در آن از جاذب پشم معدنی (دانسیته Kg/m3 80 و 100 و ضخامت cm5 و 10 ) استفاده شده است. برای تعیین تراز فشار صوت فن در کانال، دو میکروفون تعبیه شده است که با استفاده از نرم&#8204;افزار MATLAB و در پهنای باند یک سوم اکتاو باند و در دورهای متغیر از 600-2500 دور بر دقیقه صورت گرفته شده است. در این مطالعه به بررسی تعدادی از متغیرهایی که بر عملکرد سایلنسر جذبی در کانال مؤثر است پرداخته شده است و تأثیر آن&#8204;ها در کاهش تراز فشار صوت سایلنسر مورد بررسی قرار گرفته شده است.یافته&#8204;ها: حداکثر 2 دسی بل کاهش فشار صوت در فرکانس&#8204;های پایین توسط سایلنسر جذبی طراحی شده که هم سطح با کانال طراحی شده، به دست آمده است. در این مطالعه با افزایش میزان ضخامت در ماده جاذب سایلنسر جذبی تغییر چندانی در کاهش صدا وجود نداشت اما با افزایش چگالی از Kg/m380 به 100نتایج بهتری در کاهش تراز فشار صوت دیده شد و باعث افزایش میزان میزان کاهش تراز فشارصوت (NR) شد.نتیجه&#8204;گیری: با توجه به بررسی داده&amp;lrm;های حاصل از مطالعه مذکور، می&amp;lrm;توان در سیستم&amp;lrm;های تهویه از سایلنسر با ضخامت 5 سانتی متر با دانسیته Kg/m3 100 در کاهش فشار صوت در فرکانس پایین&#8204;تر از 250 هرتز به عنوان وسیله&amp;lrm;ای مؤثر استفاده کرد.&amp;nbsp;واژه&#8204;های کلیدی: فن، سایلنسر جذبی، کاهش تراز فشار صوت، دانسیته، ضخامت</abstract_fa>
	<abstract>Background: Ventilation systems in buildings are one of the most important sources of noise, which are spread into the surrounding environment through fans and channels or distributors. Since axial fans are used in industry very much and silencers are among ways to noice control. The purpose of this study is investigation on use of absorptive silencer in reduction Low-frequency noise Iranian axial fan.Methods: In this study, we used galvanized chanal 0.6 mm with 30*30 cm2 dimension and axial fan. Absorptive silencer as channel was designed to cross section of channel and silencers after embedded the absorber be identical together. Length of absorptive silencer was 50cm and there used mineral wool absorbent (density 80,100 Kg/m3 and thickness 5, 10 cm). To determine the sound pressure level in a chanal, two microphones are embedded that be accomplished by using MATLAB software in the one third of octave broadband and variable speeds 600-2500 rpm. We investigate amount of the reduction in absorption silencer sound filled with Iranian absorbing materials and influence of thickness and density of adsorbent material in silence.&amp;nbsp;Findings: The maximum 2 dB reduction is in pressure sound level at low frequencies of designed absorptive silencer that design in the chanal surface. In this study, an increase in the thickness of the absorbent material of absorption silencer, there was a little change in the volume decreasing but with increasing density from 80 to 100 Kg/m3 better results were seen to reduce noise levels and it caused to increase noise reduction rate.Conclusion: According to data from the present study we can use silencer with 5cm thick and 100 Kg / m3 density in the reduction of sound pressure level at frequencies lower than 250 Hz in the ventilation system as an effective device.&amp;nbsp;Key Words: Fan, Absorptive Silencer, Noise Reduction, Density, Thickness</abstract>
	<keyword_fa></keyword_fa>
	<keyword></keyword>
	<start_page>250</start_page>
	<end_page>257</end_page>
	<web_url>http://hsr.mui.ac.ir/browse.php?a_code=A-10-39-685&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Hossein Ali</first_name>
	<middle_name></middle_name>
	<last_name>Yousefi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حسینعلی یوسفی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460013830</code>
	<orcid>100319475328460013830</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Occupational Health Engineering, School of Health, Isfahan University of Medical Sciences, Isfahan, Iran</affiliation>
	<affiliation_fa>استادیار و عضو هیأت علمی گروه مهندسی بهداشت حرفه‌ای، دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Farhad</first_name>
	<middle_name></middle_name>
	<last_name>Forouharmajd</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فرهاد فروهرمجد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460013831</code>
	<orcid>100319475328460013831</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Department of Occupational Health Engineering, School of Health, Isfahan University of Medical  Sciences, Isfahan, Iran</affiliation>
	<affiliation_fa>استادیار و عضو هیأت علمی گروه مهندسی بهداشت حرفه‌ای، دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Leila</first_name>
	<middle_name></middle_name>
	<last_name>Maghsudian</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>لیلا مقصودیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460013832</code>
	<orcid>100319475328460013832</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Student of MS.c ,Department of Occupational Health Engineering, School of Health, Isfahan University of Medical Sciences,  Isfahan, Iran</affiliation>
	<affiliation_fa>دانشجوی کارشناسی ارشد، گروه مهندسی بهداشت حرفه ای، دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
