<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Health System Research</title>
<title_fa>مجله تحقیقات نظام سلامت</title_fa>
<short_title>J Health Syst Res</short_title>
<subject>Medical Sciences</subject>
<web_url>http://hsr.mui.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-2363</journal_id_issn>
<journal_id_issn_online>2322-5564</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.48305</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1397</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2018</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>14</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی تأثیر دو نوع جلیقه خنک‌کننده بر روی پاسخ‌های فیزیولوژیک استرین گرمایی در هنگام پوشیدن لباس حفاظتی مقاوم در برابر اسید در اتاقک شرایط جوی</title_fa>
	<title>The Impact of Two Types of Cooling Vests on Physiological Heat Strain Responses When Wearing Acid-Resistant Protective Clothing in Climatic Chamber</title>
	<subject_fa>آموزش بهداشت و ارتقاء سلامت </subject_fa>
	<subject>education health and promotion</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>مقدمه: با توجه به بروز استرین گرمایی در هنگام کاربرد لباس&#8204;های حفاظتی مقاوم در برابر اسید به عنوان لباس کار در محیط&#8204;های کاری، مطالعه حاضر با هدف تعیین تأثیر عملکرد دو نوع جلیقه خنک&#8204;کننده بر روی شاخص&#8204;های استرین گرمایی در هنگام پوشیدن لباس&#8204;های حفاظتی مقاوم در برابر اسید انجام شد.روش&#8204;ها: این مطالعه از نوع تجربی بود که در اتاقک شرایط جوی با دمای 40 درجه سانتی&#8204;گراد و رطوبت 25 درصد، بر روی 10 دانشجوی پسر سالم که لباس مقاوم در برابر اسید پوشیده بودند، انجام گرفت. هر فرد سه بار و به مدت 90 دقیقه بر روی تردمیل با سرعت 8/2 کیلومتر در ساعت و شیب صفر درجه، یک بار بدون جلیقه (گروهA )، یک بار با جلیقه ژل یخ (گروه B) و یک بار هم با جلیقه مواد تغییر فاز پارافینی (گروه C) راه &#8204;رفت. ضربان قلب، دمای دهانی و دمای پوست در طول انجام آزمون اندازه&#8204;گیری گردید.یافته&#8204;ها: میانگین ضربان قلب در گروه&#8204;های A، B و C به ترتیب 0/104، 2/97 و 7/97 ضربان در دقیقه گزارش شد. میانگین دمای پوست به ترتیب 1/37، 1/31 و 2/33 درجه سانتی&#8204;گراد و میانگین دمای دهانی به ترتیب 9/36، 7/36 و 6/36 درجه سانتی&#8204;گراد بود. اختلاف معنی&#8204;داری بین میانگین شاخص&#8204;های فیزیولوژیک در گروه&#8204;های B و C در مقایسه با گروه A وجود داشت.نتیجه&#8204;گیری: در هنگام استفاده از لباس کار ضد اسید، پوشیدن جلیقه خنک&#8204;کننده ژل یخ و تغییر فاز پارافینی از طریق کاهش دادن شاخص&#8204;های فیزیولوژیک، سطح استرین گرمایی را تا حد قابل قبولی کاهش می&#8204;دهند.</abstract_fa>
	<abstract>Background: Rigarding the occurrence of heat strain when using acid-resistant protective work clothing in the workplace, this study aimed to determine the performance of two types of cooling vests on heat strain indices in hot conditions when wearing acid-resistant protective clothing.Methods: This experimental study was conducted on ten healthy boy students in hot conditions of temperature of 40 &amp;deg;C and relative humidity (RH) of 25% when they wearied acid-resistant protective clothing. Each participant was contributed in three trials including without cooling vest (A), with ice gel cooling vest (B) , and phase change material paraffin (C). In each trial, participant walked on tread mill for 90 minutes. Heart rate, oral temperature, and skin temperature were measured in regular times.Findings: The mean of heart rate was 104.0, 97.2, and 97.7 beat/minute in A, B, and C trials, respectively. Moreover, skin temperature was 37.1 &amp;deg;C, 31.1 &amp;deg;C, and 33.2 &amp;deg;C, and oral temperature was 36.3 &amp;deg;C , 33.0 &amp;deg;C, and 34.0 &amp;deg;C in A, B, and C trials, respectively. There was significant difference in physiological heat strain indices between B and C trials with A trial.Conclusion: When using acid-resistant work clothing, wearing ice gel cooling vest and phase change material paraffin can reduce physiological heat strain indices.</abstract>
	<keyword_fa>استرس حرارتی, خنک, لباس, دمای بدن, مقاوم به اسید,</keyword_fa>
	<keyword></keyword>
	<start_page>258</start_page>
	<end_page>264</end_page>
	<web_url>http://hsr.mui.ac.ir/browse.php?a_code=A-10-39-914&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Habibollah </first_name>
	<middle_name></middle_name>
	<last_name>Dehghan</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حبیب‌اله دهقان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460010691</code>
	<orcid>100319475328460010691</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Associate Professor, Department of Occupational Health Engineering, School of Health, Isfahan University of Medical Sciences, Isfahan, Iran</affiliation>
	<affiliation_fa>دانشیار، گروه مهندسی بهداشت حرفه‌ای، دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Kobra </first_name>
	<middle_name></middle_name>
	<last_name>Maghsoudi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کبری مقصودی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460010692</code>
	<orcid>100319475328460010692</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>MSc Student, Student Research Committee AND Department of Occupational Health Engineering, School of Health, Isfahan University of Medical Sciences, Isfahan, Iran</affiliation>
	<affiliation_fa>دانشجوی کارشناسی ارشد، کمیته تحقیقات دانشجویی و گروه مهندسی بهداشت حرفه ای، دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
