<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Health System Research</title>
<title_fa>مجله تحقیقات نظام سلامت</title_fa>
<short_title>J Health Syst Res</short_title>
<subject>Medical Sciences</subject>
<web_url>http://hsr.mui.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2783-4093</journal_id_issn>
<journal_id_issn_online>2322-5564</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.48305</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1402</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2023</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>19</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بهینه‌سازی تصفیه‌خانه فاضلاب به روش لجن فعال با استفاده از نرم‌افزار GPS-X</title_fa>
	<title>Optimization of Wastewater Treatment Plant by Activated Sludge Method Using GPS-X Software</title>
	<subject_fa>مهندسی بهداشت محیط </subject_fa>
	<subject>Environmental Health Engineering</subject>
	<content_type_fa>كاربردي</content_type_fa>
	<content_type>Applicable</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt;مقدمه:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt; &lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt;هدف از انجام پژوهش حاضر، مدل&#8204;سازی یک تصفیه&#8204;خانه فاضلاب واقعی در حال بهره&#8204;برداری با استفاده از نرم&#8204;افزار &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;GPS-X&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt; بود. بدین ترتیب، نتایج خروجی نرم&#8204;افزار با نتایج آزمایش&#8204;های پساب تصفیه&#8204;خانه فاضلاب مورد نظر صحت&#8204;سنجی شد. سپس نرخ لجن برگشتی، لجن بازچرخش شده و لجن دفع شده تصفیه&#8204;خانه فاضلاب به روش &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;Modified Ludzack-Ettinger&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt; (&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;MLE&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt;) بهینه&#8204;سازی گردید؛ به صورتی که بیشترین تأثیر را روی کیفیت پساب خروجی به خصوص شاخص&#8204;های &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;Chemical oxygen demand&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt; (&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;COD&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt;) و &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt;نیترات &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt;داشته باشد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:115%&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt;روش&#8204;ها:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt; &lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt;ابتدا با استفاده از داده&#8204;های موجود تصفیه&#8204;خانه فاضلاب مورد نظر، فرایندهای آن در نرم&#8204;افزار مدل شد و انطباق مدل با تصفیه&#8204;خانه موجود بررسی گردید. بعد از صحت&#8204;سنجی نرم&#8204;افزار، به منظور بررسی شاخص&#8204;های مؤثر بر فرایند لجن فعال شامل نرخ لجن برگشتی، نرخ لجن مازاد و نرخ لجن بازچرخش داخلی در تصفیه مواد آلی و نیتروژن، شاخص&#8204;های &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;COD&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt;، نیترات و آمونیاک به عنوان شاخص سنجش آلودگی مورد بررسی قرار گرفت. همچنین، فرایند &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;MLE&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt; جهت حذف نیتروژن در نرم&#8204;افزار مدل&#8204;سازی شد. سپس با تغییر شاخص&#8204;ها و بررسی خروجی&#8204;های به دست آمده، نتایج در خصوص اثر افزایش نرخ بازچرخش لجن در غلظت &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;COD&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt; در پساب خروجی و اثر افزایش و کاهش نرخ بازچرخش داخلی و نرخ لجن دفعی در حذف &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;COD&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt; بررسی گردید. همچنین، اثر متقابل تغییرات بازچرخانی داخلی لجن و لجن برگشتی و مقدار لجن مازاد دفعی بر حذف نیترات به وسیله نمودارهای مختلف نشان داده شد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:115%&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt;یافته&#8204;ها:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt; ضمن صحت&#8204;سنجی نرم&#8204;افزار در مطالعه حاضر، نتایج حاصل از طراحی آزمایش نشان داد که نرخ لجن برگشتی و بازچرخش داخلی دارای اثرات متقابل نسبت به یکدیگر در حذف &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;COD&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;&quot;&gt;&lt;span style=&quot;line-height: 115%;&quot;&gt;&lt;span b=&quot;&quot; style=&quot;&quot; zar=&quot;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt; و &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt;نیترات &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;بودند&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt; و در حالت بهینه بهره&#8204;برداری و طراحی، نسبت 54/0 برای لجن برگشتی و یک برابر بازچرخانی داخلی و نسبت 021/0 برای لجن دفعی، بیشترین تأثیر را بر راندمان حدف &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;COD&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt; و نیترات و افزایش کیفیت پساب خروجی داشت.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:115%&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt;نتیجه&#8204;گیری:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt; استفاده از نرم&#8204;افزار &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;GPS-X&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span b=&quot;&quot; style=&quot;font-family:&quot; zar=&quot;&quot;&gt; می&#8204;تواند در مدل&#8204;سازی و بهینه&#8204;سازی فرایندهای تصفیه فاضلاب مورد استفاده قرار گیرد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;Background:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt; The purpose of this study was to model a real wastewater treatment plant in operation with GPS-X software. In the following, the verification of the output results of the software was done with the results of the effluent tests of the discussed sewage treatment plant. Then, the rate of return sludge, recycled sludge, and disposed sludge of the wastewater treatment plant was optimized by &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;em&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;background:white&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;Modified Ludzack&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/em&gt;&lt;em&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;background:white&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;-&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/em&gt;&lt;em&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;background:white&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;Ettinger (MLE&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/em&gt;&lt;em&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;background:white&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt;)&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/em&gt;&lt;em&gt;&lt;span style=&quot;font-size:10.5pt&quot;&gt;&lt;span style=&quot;background:white&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&lt;span style=&quot;font-style:normal&quot;&gt; method&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/em&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;, so that it has the greatest effect on the quality of the effluent, especially chemical oxygen demand (COD) and nitrate (NO&lt;sub&gt;3&lt;/sub&gt;) parameters.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:115%&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;Methods:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt; First, using the available data of an operating wastewater treatment plant, the processes of the treatment plant were modeled in the software and the compatibility of the model with the existing treatment plant was checked. After the validation of the software, in order to check the parameters affecting the activated sludge process, including return sludge rate, excess sludge rate, and internal recirculation sludge rate in the treatment of organic matter and nitrogen, COD, NO&lt;sub&gt;3&lt;/sub&gt;, and ammonia parameters were investigated as indicators of pollution. In addition, the MLE process for nitrogen removal was modeled in the software. After performing the modeling by changing the parameters and checking the resulting outputs, the results regarding the effect of increasing the sludge recirculation rate on the COD concentration in the effluent and the effect of increasing and decreasing the internal recirculation rate and the disposal sludge rate on COD removal were examined. In addition, the mutual effect of changes in internal sludge recycling and return sludge and the amount of excess sludge disposal on NO&lt;sub&gt;3&lt;/sub&gt; removal was shown by different graphs.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:115%&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;Findings:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt; In this study, while validating the software, the results of the experiment design showed that the return sludge rate and the internal recirculation rate had mutual effects on each other in the removal of COD and NO&lt;sub&gt;3&lt;/sub&gt;, and in the optimal mode of operation and design, the ratio of 0.54 for return sludge and one-time internal recycling and ratio of 0.021 for disposal sludge had the greatest effect on COD and NO&lt;sub&gt;3&lt;/sub&gt; removal target efficiency and increasing the effluent quality.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:115%&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;Conclusion:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt; GPS-X software can be used in the modeling and optimization of wastewater treatment processes.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>فاضلاب, لجن, بازچرخش لجن, اکسیژن مورد نیاز شیمیایی, نیترات</keyword_fa>
	<keyword>Wastewater, Sludge, Sludge recirculation, COD, Nitrates</keyword>
	<start_page>117</start_page>
	<end_page>125</end_page>
	<web_url>http://hsr.mui.ac.ir/browse.php?a_code=A-10-272-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Seyed Mahdy </first_name>
	<middle_name></middle_name>
	<last_name>Mirian</last_name>
	<suffix></suffix>
	<first_name_fa>سید مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>میریان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mirian.tarhafra@chmail.ir</email>
	<code></code>
	<orcid>0009-0003-8503-8293</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>MSc Student, Daneshpajoohan Pishro Higher Education Institute (DHEI) AND Tarhafra Consulting Engineers Company, Isfahan, Iran</affiliation>
	<affiliation_fa>دانشجوی کارشناسی ارشد، مؤسسه آموزش عالی دانش‌پژوهان پیشرو و شرکت مهندسین مشاور طرح‌افرا، اصفهان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Afshin</first_name>
	<middle_name></middle_name>
	<last_name>Ebrahmi</last_name>
	<suffix></suffix>
	<first_name_fa>افشین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ابراهیمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>a_ebrahimi@hlth.mui.ac.ir</email>
	<code></code>
	<orcid>0000-0002-3640-087X</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Professor, Department of Environmental Health Engineering, School of Health AND Environment Research Center, Research Institute for Primordial and Non-communicable Disease, Isfahan University of Medical Sciences, Isfahan, Iran</affiliation>
	<affiliation_fa>استاد، گروه مهندسی بهداشت محیط، دانشکده بهداشت و مرکز تحقیقات محیط زیست، پژوهشکده پیشگیری اولیه از بیماری‌های غیر واگیر، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
