<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Health System Research</title>
<title_fa>مجله تحقیقات نظام سلامت</title_fa>
<short_title>J Health Syst Res</short_title>
<subject>Medical Sciences</subject>
<web_url>http://hsr.mui.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2783-4093</journal_id_issn>
<journal_id_issn_online>2322-5564</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.48305</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1390</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2011</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>7</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>کاهش صدای فن و کانال هوا با استفاده از پلنوم (plenum) طبق دستورالعمل ASHRAE</title_fa>
	<title>Noise Reduction of the Fan and Air Ducts Using a Plenum Chamber Produced Based on ASHRAE Guidelines</title>
	<subject_fa>آموزش بهداشت و ارتقاء سلامت </subject_fa>
	<subject>education health and promotion</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>چکیده مقدمه: جهت حذف و کاهش صدا در سیستم&#8204;های تهویه از پیش طراحی و نصب شده، باید میزان صدا را در فضای تحت پوشش سیستم HVAC با استفاده از روش ASHRAE و محفظه&#8204;های پلنوم (Plenum) کنترل نمود. روش&#8204;ها: محفظه به ابعاد 5/1 متر طول، 2/1 متر ارتفاع و 1/1 متر عرض از جنس آهن گالوانیزه به ضخامت 6/0 میلی&#8204;متر با دو دهانه ورودی و خروجی به ابعاد 20 &amp;times; 40 سانتی&#8204;متر بر اساس نسبت&#8204;های ابعاد مورد بحث در استاندارد اشری ساخته شد. سطح داخلی این محفظه با استفاده از جاذب پشم معدنی با دانسیته حجمی kg/m3 80 و ضخامت 10 سانتی&#8204;متر پوشانده شد. یافته&#8204;ها: میزان کاهش صدا در فرکانس&#8204;های اکتاو شبکه A حداقل 3/2 و حداکثر 2/13 دسی&#8204;بل بوده است. اگر چه این میزان کاهش در فرکانس 250 هرتز دیده می&#8204;شود، ولی به طور کلی بیشترین کاهش صدا در فرکانس&#8204;های میانی و بالا وجود دارد. نتیجه&#8204;گیری: بهترین نتیجه گرفته شده بر اساس استاندارد اشری این است که ابعاد محفظه و ویژگی&#8204;های آکوستیکی مواد جاذب در میزان کاهش صدای محفظه نقش مهمی دارند. در حقیقت می&#8204;توان با تغییر ابعاد محفظه، به نتایج بهتری از کاهش صدای سیستم&#8204;&#8204;های تهویه و کانال هوا دست پیدا نمود. برای حذف بهتر صدای کم فرکانس می&#8204;توان از محفظه بزرگ&#8204;تری استفاده نمود. واژه&#8204;های کلیدی: نویز، صدا، کنترل، تهویه، محفظه، کانال هوا.</abstract_fa>
	<abstract>Abstract Background: In order to eliminate and reduce noise in predesigned and installed heating, ventilation, and air-conditioning (HVAC) systems, noise control in HVAC system areas needs to be performed using plenum chambers based on ASHRAE method. Methods: A plenum chamber made of galvanized iron was produced based on ASHRAE standards. The length, height, and width of the chamber were 1.5 meters, 1.1 meters and 1.2 meters, respectively. Two input and output openings (40 &amp;times; 20 cm) were also made. The internal surface of the chamber was lined by 10 cm thick mineral wool with a density of 80 kg/m3. Findings: The results show a noise reduction of 2.3 to 13.2 dB with a peak at 250 Hz in 1/1 octave band frequency based on ASHRAE standard method. Generally, highest levels of noise reduction were observed in medium to high frequencies. Conclusion: The most important conclusion revealed by this study is that based on ASHRAE standard, dimensions of the plenum chamber and acoustic specifications of absorbent material applied into the chamber can highly affect the level of noise reduction. In fact, we can change the noise reduction value by changing the dimensions of the plenum. For low frequencies, as said before, it is better to use a bigger plenum chamber.</abstract>
	<keyword_fa></keyword_fa>
	<keyword>Noise, Sound, Control, Ventilation, Plenum, Air duct.</keyword>
	<start_page>0</start_page>
	<end_page>0</end_page>
	<web_url>http://hsr.mui.ac.ir/browse.php?a_code=A-10-39-144&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Farhad</first_name>
	<middle_name></middle_name>
	<last_name>Forouharmajd</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فرهاد فروهرمجد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460015202</code>
	<orcid>100319475328460015202</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Member Department of Occupational Health, School of Public Health, Isfahan University of Medical Sciences, Isfahan and PhD Candidate,  Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>عضو گروه بهداشت حرفه‌ای، دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان و دانشجوی دکتری بهداشت حرفه‌ای با گرایش کنترل صدا و ارتعاش، دانشگاه علوم پزشکی تهران، تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Parvin </first_name>
	<middle_name></middle_name>
	<last_name>Nassiri</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>پروین نصیری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460015203</code>
	<orcid>100319475328460015203</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Professor, Department of Occupational Health, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>- استاد گروه بهداشت حرفه ای، دانشکده بهداشت، دانشگاه علوم پزشکی تهران، تهران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
