<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Health System Research</title>
<title_fa>مجله تحقیقات نظام سلامت</title_fa>
<short_title>J Health Syst Res</short_title>
<subject>Medical Sciences</subject>
<web_url>http://hsr.mui.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-2363</journal_id_issn>
<journal_id_issn_online>2322-5564</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.48305</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1392</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2014</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>9</volume>
<number>11</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی آلودگی صدای کوره بلند در یک صنعت فولاد به منظور کنترل صدا</title_fa>
	<title>Study of Noise pollution in the blast furnace of a steel industry in order to noise control</title>
	<subject_fa>آموزش بهداشت و ارتقاء سلامت </subject_fa>
	<subject>education health and promotion</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>مقدمه: در صنعت فولاد کوره&#8204;های با سوخت کک که جهت ذوب سنگ آهن و تولید چدن مورد استفاده قرار می&amp;lrm;گیرند از منابع صدای آزاردهنده محسوب می&amp;lrm;گردند. هدف مطالعه حاضربررسی آلودگی صدای کوره بلند یک صنعت فولاد و مطالعه ویژگی&amp;lrm;های صدای آن به منظور طرح کنترل صدا بود.&amp;nbsp;&amp;nbsp;&amp;nbsp; روش&#8204;ها: اندازه&amp;lrm;گیری تراز صدا و تجزیه فرکانسی آن با استفاده از ترازسنج صدا مدلCell.450 و دزیمتری صدا با استفاده از دزیمتر مدلTES-1345انجام گردید. توزیع تراز صدا در محوطه کوره بصورت نقشه صوتی با استفاده از نرم افزار SURFERتهیه گردید و ویژگی&amp;lrm;های عایق&amp;lrm;بندی صوتی اتاق کنترل کوره و اتاق استراحت کارگران کوره مورد تحلیل آکوستیکی قرارگرفت. اصلاح اتاق استراحت کارگران و طراحی مجدد درب و پنجره اتاق کنترل پیشنهاد و میزان تاثیر مداخلات برآورد گردید.&amp;nbsp;&amp;nbsp; یافته&amp;lrm;ها:تراز کلی فشار صوت در محوطه کوره dB(Lin) 3/90 و فرکانس غالب آن Hz4000 در شبکه &amp;nbsp;خطی (Lin) تعیین شد. میزان افت انتقال صوت دیوار جداکننده اتاق کنترل و اتاق استراحت کارگران کوره به ترتیب dB 3/10 و dB 23/4&amp;nbsp; تعیین شد. دز صدای دریافتی کارگران240درصد تعیین گردید. میزان کاهش تراز صوت اتاق&#8204;ها با اجرای طرح&#8204;های کنترلی ارائه شده بر مبنای عایق بندی صوت در واحد کوره dB 30 برآورد شده است. نتیجه&amp;lrm;گیری: عامل اصلی آلودگی صدا در اطراف کوره ناشی از جریان آشفته و متلاطم هوا در کانال&#8204;&amp;zwj;&#8204;های هوای ورودی به کوره بود که با توجه به امکان سنجی صورت گرفته پناهگاه صوتی استاندارد در قالب اتاق کنترل و استراحت موثرترین روش کنترل&amp;nbsp; مواجهه کارگران با صدا ارائه و طراحی گردیدکه براین اساس میزان دز صدای دریافتی کارگران به کمتر از 100 درصد کاهش خواهد یافت. &amp;nbsp; واژه&#8204;های کلیدی : تحلیل آکوستیکی، کوره بلند، کنترل صدا، صنعت فولاد، پناهگاه صوتی &amp;nbsp; &amp;nbsp;</abstract_fa>
	<abstract>Background:In the steel industry, coke-fueled furnaces are used for smelting iron ore to produce cast iron are considered as sources of annoying noise.This study aims to evaluate the noise pollution blast furnace and sound source characteristics in order to present noise control measures in the steel industry. Methods: Measurement of noise level and its frequency analysis was performed using sound level meter model of CASELLA-Cell.450 .Dosimetery in order to worker exposure was performed using the dosimeter model TES-1345.Distribution of noise level in the furnace area in form of noise map was provided using Surfer software. In addition, acoustic analysis of control and furnace workers rest rooms was performed in view point of and insulation.Redesign of door and window of control room and reform of workers&amp;#39; rest room were proposed and the efficiency of these interventions was estimated. Findings:The total sound pressure level in the furnace workroom was 90.3dB(L) and the dominant frequency was 2000Hz. Sound transmission loss of the wall dividing the control room and rest room workers furnace 10.3 and 4.23dB, respectively. The average of noise dose in furnace worker was 240%. And sound transmission loss of the new The performance of the proposed control schemes based on sound insulation of rooms was estimated equal to 30dB. Conclusion: The main cause of noise pollution caused by turbulent air flow in the air ducts furnace. The acoustic Shelter was designed for standard control room and rest as the most effective method of controlling workers&amp;#39; exposure to noise. Accordingly, the workers received a noise dose of less than 100% can reduce. &amp;nbsp;</abstract>
	<keyword_fa></keyword_fa>
	<keyword></keyword>
	<start_page>1263</start_page>
	<end_page>1272</end_page>
	<web_url>http://hsr.mui.ac.ir/browse.php?a_code=A-10-39-417&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name>Rostam Golmohammadi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رستم گلمحمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460015353</code>
	<orcid>100319475328460015353</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation> PhD, Department of occupational health, Hamadan University of Medical Sciences- Hamedan , Faculty of Health. Hamadan, Iran</affiliation>
	<affiliation_fa>دانشیار گروه مهندسی بهداشت حرفه‎ای، دانشکده بهداشت و مرکز تحقیقات علوم بهداشتی، دانشگاه علوم پزشکی همدان، همدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name>Mohsen Aliabadi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>محسن علی آبادی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460015354</code>
	<orcid>100319475328460015354</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>PhD, Department of occupational health, Hamadan University of Medical Sciences- Hamedan, Faculty of Health, Hamadan, Iran</affiliation>
	<affiliation_fa>ستادیار گروه مهندسی بهداشت حرفه‎ای، دانشکده بهداشت، دانشگاه علوم پزشکی و خدمات بهداشتی درمانی همدان، همدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name>Ebrahim Darvishi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ابراهیم درویشی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460015355</code>
	<orcid>100319475328460015355</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Kurdistan Environmental Health Research Center, Lecturer. Department of occupational health, Kurdistan University of Medical Sciences, Faculty of Health. Sanandaj, Iran (Corresponding Author)Email: darvishi.hse@gmail.com </affiliation>
	<affiliation_fa>عضو مرکز تحقیقات بهداشت محیط و مربی گروه مهندسی بهداشت حرفه‎ای،  دانشکده بهداشت، دانشگاه علوم پزشکی و خدمات بهداشتی درمانی کردستان، سنندج، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
