<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Health System Research</title>
<title_fa>مجله تحقیقات نظام سلامت</title_fa>
<short_title>J Health Syst Res</short_title>
<subject>Medical Sciences</subject>
<web_url>http://hsr.mui.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-2363</journal_id_issn>
<journal_id_issn_online>2322-5564</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.48305</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1394</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2015</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<volume>11</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مدیریت و بهینه‌سازی میزان تزریق کلر در شبکه‌های توزیع آب با استفاده از مدل Water Gems v3/0</title_fa>
	<title>Management and optimization of Injection rate of chlorine in water distribution networks using water Gems v3/0</title>
	<subject_fa>آموزش بهداشت و ارتقاء سلامت </subject_fa>
	<subject>education health and promotion</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>مقدمه: آب آشامیدنی به روش&#8204;های مختلفی گندزدایی می&#8204;شود که متداول&#8204;ترین و ارزان&#8204;ترین روش آن، کلرزنی است. یکی از مهم&#8204;ترین مسائل در زمینه کلرزنی، مکان و میزان تزریق کلر است که باید به گونه&#8204;ای انتخاب شود که میزان کلر باقیمانده در کلیه نقاط یک شبکه توزیع آب شهری در محدوده استاندارد بوده و هم&#8204;چنین هزینه&#8204;های مربوطه حداقل گردد. در این تحقیق سعی شده با اجرای برنامه برای دو شبکه توزیع آب شهری، میزان کلر باقیمانده در لوله&#8204;ها و مقدار کلر مصرفی در نقاط مختلف شبکه مورد مقایسه و تحلیل کیفی قرار گیرد.روش&#8204;ها: به&#8204;منظور مدل&#8204;سازی شبکه از نرم&#8204;افزار water Gems v3/0 استفاده شد. با استفاده از این نرم&#8204;افزار، شبکه به دو صورت ثقلی و پمپاژ مستقیم، مدل و طراحی گردید.یافته&#8204;ها: با حل دو مدل کاربردی از شبکه&#8204;های آبرسانی توسط نرم&#8204;افزار، کارایی هر دو شبکه در جهت تعیین میزان بهینه تزریق کلر نشان داده شد. نتایج نشان داد که میزان کلر باقی&#8204;مانده در 62٪ از لوله&#8204;های شبکه پمپاژ مستقیم در حد استاندارد و در 100٪ از لوله&#8204;های موجود در شبکه توزیع ثقلی کمتر از حد استاندارد است. هم&#8204;چنین میزان کلر مصرفی در شبکه پمپاژ مستقیم 5/6٪ کمتر از شبکه توزیع ثقلی محاسبه گردید.نتیجه&#8204;گیری: این تحقیق نشان داد که بهینه&#8204;سازی تزریق کلر به شبکه&#8204;های با پمپاژ مستقیم در مقایسه با شبکه&#8204;های توزیع ثقلی، بیشتر امکان&#8204;پذیر بوده و هم&#8204;چنین به میزان کلر مصرفی کمتری نیاز می&#8204;باشد.واژه&#8204;های کلیدی: سیستم آبرسانی، شبکه توزیع، کلر باقیمانده، تحلیل کیفی، water Gems</abstract_fa>
	<abstract>&amp;nbsp;Background: Drinking water is disinfected in different ways. The most common and cheapest one is chlorination. The most important issue in chlorination is place and rate of chlorin injection which should be selected in such a way that residual chlorine in all parts of water distribution network is standard and the related expenditure is minimal. Performing a program for two distribution networks of urban water, this paper aimed to analyze and compare the rate of chlorine remained in the pipe lines and the amount of chlorine used in different parts of the network.Methods: In order to model the networks, the Water Gems software V3/0 was used, and the two networks were modeled and designed in the form of gravity and direct pumping.Findings: Solving the two practical models of water supply networks by the software, the efficiency of these networks was evaluated to determine the optimum injection rate of chlorine. Findings indicated that the residual chlorine in 62% of the tap water of direct pumping network was close to standard limit and that in 100% of gravity network was less than the standard limit. In addition, the amount of used chlorine in the direct pumping network was 6/5% less than that in the gravity one.Conclusion: This study revealed that the optimization of chlorine injection into the networks with direct pumping is possible, applicable and needs less chlorinecompared to the gravity distribution networks. Key Words: Water Supply System, Distribution Network, Residual Chlorine, Qualitative Analysis, Water Gems software</abstract>
	<keyword_fa></keyword_fa>
	<keyword></keyword>
	<start_page>360</start_page>
	<end_page>370</end_page>
	<web_url>http://hsr.mui.ac.ir/browse.php?a_code=A-10-39-675&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Amin</first_name>
	<middle_name></middle_name>
	<last_name>Taji Eshkaftaki</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>امین تاجی اشکفتکی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460013901</code>
	<orcid>100319475328460013901</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>MSc, Department of Civil Engineering, School of Engineering, Yasouj University of Islamic Azad, Yasouj, Iran</affiliation>
	<affiliation_fa>دانشجوی کارشناسی ارشد، گروه مهندسی عمران، دانشکده فنی مهندسی، دانشگاه آزاد اسلامی واحد یاسوج، یاسوج، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mehraban</first_name>
	<middle_name></middle_name>
	<last_name>Sadeghi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مهربان صادقی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460013902</code>
	<orcid>100319475328460013902</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Associate Professor, Department of Environmental Health Engineering, School of Health, Shahrekord University of Medical  Sciences, Shahrekord, Iran</affiliation>
	<affiliation_fa>دانشیار،گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی شهرکرد، شهرکرد، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hassan</first_name>
	<middle_name></middle_name>
	<last_name>Hashemi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حسن هاشمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460013903</code>
	<orcid>100319475328460013903</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Research Center for Health Sciences, Shiraz University of Medical Sciences, Shiraz, Iran </affiliation>
	<affiliation_fa>مرکز تحقیقات علوم بهداشتی، دانشگاه علوم پزشکی شیراز، شیراز، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Behnam </first_name>
	<middle_name></middle_name>
	<last_name>Hoseyni</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بهنام حسینی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460013904</code>
	<orcid>100319475328460013904</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Lecturer, Department of Civil Engineering, School of Engineering, Yasouj University of Islamic Azad, Yasouj, Iran</affiliation>
	<affiliation_fa>مربی، گروه عمران، دانشکده فنی مهندسی، دانشگاه آزاد اسلامی واحد یاسوج، یاسوج، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
