<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Health System Research</title>
<title_fa>مجله تحقیقات نظام سلامت</title_fa>
<short_title>J Health Syst Res</short_title>
<subject>Medical Sciences</subject>
<web_url>http://hsr.mui.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-2363</journal_id_issn>
<journal_id_issn_online>2322-5564</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.48305</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>13</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>حذف آرسنیک سه ظرفیتی و کروم شش ظرفیتی از محلول‌های آبی با استفاده از نانو ذرات آهن صفر ظرفیتی (nZVI) و تعیین ایزوترم‌های جذب</title_fa>
	<title>Removal of Arsenic (III) and Chromium (VI) from Aqueous Solutions Using Nanoscale ZeroValent Iron (nZVI) Particles and Determining Adsorption Isotherms</title>
	<subject_fa>آموزش بهداشت و ارتقاء سلامت </subject_fa>
	<subject>education health and promotion</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>مقدمه: آرسنیک و کروم از جمله فلزات سنگین است که به عنوان آلاینده&#8204;های متداول منابع آب و فاضلاب مطرح می&#8204;باشد. نانو ذرات آهن با ظرفیت صفر (Nano zero valent iron یا nZVI) به دلیل ظرفیت بالای خود قادر به حذف این آلاینده&#8204;ها می&#8204;باشد. هدف از انجام مطالعه حاضر، بررسی حذف آرسنیک (III) و کروم (VI) از محلول&#8204;های آبی با استفاده از nZVI و تعیین ایزوترم&#8204;های جذب بود.روش&#8204;ها: جهت تعیین و تأثیر پارامترهایی مانند pH، غلظت اولیه، مقدار nZVI و زمان بر حذف آرسنیک و کروم از نرم&#8204;افزار طراحی آزمایش استفاده شد. غلظت نهایی فلزات توسط دستگاه پلاسمای القایی جفت الکترونی (ICP یا Inductively coupled plasma) اندازه&#8204;گیری شد. سپس، بهترین ایزوترم&#8204;های جذب تعیین گردید.یافته&#8204;ها: نتایج نشان دهنده حذف بهینه آرسنیک در غلظت اولیه 10 میلی&#8204;گرم بر لیتر، زمان 5 دقیقه، 7 = pH و مقدار nZVI برابر 5 گرم بر لیتر بود. حذف آرسنیک توسط nZVI در غلظت&#8204;های مختلف از ایزوترم&#8204;های جذب Langmuir پیروی کرد. واکنش آرسنیک در حضور nZVI در محیط خنثی و در حضور غلظت بالای nZVI بسیار سریع رخ داد. کارایی حذف آرسنیک با افزایش غلظت رابطه عکس داشت. کارایی حذف کروم توسط nZVI بسیار پایین بود.نتیجه&#8204;گیری: نتایج نشان داد که nZVI در حذف آرسنیک از محلول&#8204;های آبی دارای کارایی بالایی است. بنابراین، می&#8204;توان از آن در حذف این فلز از آب&#8204;های آلوده و فاضلاب&#8204;های صنعتی استفاده نمود، اما کارایی حذف کروم توسط nZVI بسیار کم می&#8204;باشد.</abstract_fa>
	<abstract>Background: Arsenic and chromium are heavy metals and common pollutants of water and wastewater sources. Nanoscale zerovalent iron (nZVI) can remove these pollutants due to their high potency. The aim of the present study was the removal of arsenic (III) and chromium (VI) from aqueous solutions using nZVI and determining adsorption isotherms.Methods: The Design-Expert software was used to determine the effect of different parameters such as pH, initial concentration, nZVI dosage, and contact time on arsenic and chromium removal. The final concentration of metals was measured using inductivity coupled plasma (ICP). Then, the best fitted adsorption isotherms were determined.Findings: The results showed that the optimum removal of arsenic occurred in the initial concentration of 10 mg/l, time of 5 minutes, pH of 7, and nZVI dosage of 5 g/l. Arsenic removal with nZVI in different concentrations followed the Langmuir isotherms. The arsenic response occurred rapidly with high concentration of nZVI in neutral environment. Arsenic removal efficiency had an inverse relationship with increased concentration. The chromium removal efficiency with nZVI was low.Conclusion: The results showed that nZVI had high efficiency in arsenic removal from aqueous solutions. Therefore, it can be used for the removal of this metal from polluted water and industrial wastewater. Nevertheless, chromium removal efficiency was low with nZVI.</abstract>
	<keyword_fa></keyword_fa>
	<keyword></keyword>
	<start_page>126</start_page>
	<end_page>133</end_page>
	<web_url>http://hsr.mui.ac.ir/browse.php?a_code=A-10-39-808&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Maliheh </first_name>
	<middle_name></middle_name>
	<last_name>Moazeni</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ملیحه موذنی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460011254</code>
	<orcid>100319475328460011254</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>MSc Student, Student Research Committee, Department of Environmental Health Engineering, School of Health, Isfahan University of Medical  Sciences, Isfahan, Iran </affiliation>
	<affiliation_fa>دانشجوی کارشناسی ارشد، کمیته تحقیقات دانشجویی، گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Afshin </first_name>
	<middle_name></middle_name>
	<last_name>Ebrahimi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>افشین ابراهیمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460011255</code>
	<orcid>100319475328460011255</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Associate Professor, Environmental Research Center, Research Institute for Primordial Prevention of Non-Communicable Disease AND  Department of Environmental Health Engineering, School of Health, Isfahan University of Medical Sciences, Isfahan, Iran</affiliation>
	<affiliation_fa>دانشیار، مرکز تحقیقات محیط زیست، پژوهشکده پیشگیری از بیماری‌های غیر واگیر و گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Nasim </first_name>
	<middle_name></middle_name>
	<last_name>Rafiei</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نسیم رفیعی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460011256</code>
	<orcid>100319475328460011256</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>MSc Student, Student Research Committee, Department of Environmental Health Engineering, School of Health, Isfahan University of Medical  Sciences, Isfahan, Iran </affiliation>
	<affiliation_fa>دانشجوی کارشناسی ارشد، کمیته تحقیقات دانشجویی، گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hamid Reza </first_name>
	<middle_name></middle_name>
	<last_name>Pourzamani</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حمیدرضا پورزمانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460011257</code>
	<orcid>100319475328460011257</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Associate Professor, Environmental Research Center, Research Institute for Primordial Prevention of Non-Communicable Disease AND  Department of Environmental Health Engineering, School of Health, Isfahan University of Medical Sciences, Isfahan, Iran</affiliation>
	<affiliation_fa>دانشیار، مرکز تحقیقات محیط زیست، پژوهشکده پیشگیری از بیماری‌های غیر واگیر و گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
