<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Health System Research</title>
<title_fa>مجله تحقیقات نظام سلامت</title_fa>
<short_title>J Health Syst Res</short_title>
<subject>Medical Sciences</subject>
<web_url>http://hsr.mui.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2783-4093</journal_id_issn>
<journal_id_issn_online>2322-5564</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.48305</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1396</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2018</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>13</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>افت جایگذاری ایرپلاگ در طول‌های مختلف کانال گوش شبیه‌سازی شده</title_fa>
	<title>The Decrease in Insertion of Earplug in Different Lengths of Simulated Ear Canal</title>
	<subject_fa>آموزش بهداشت و ارتقاء سلامت </subject_fa>
	<subject>education health and promotion</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>مقدمه: ایرپلاگ به عنوان یکی از تجهیزات حفاظتی سیستم شنوایی، عملکرد متفاوتی در فرکانس&#8204;های مختلف دارد. پژوهش حاضر با شبیه&#8204;سازی مدلی از کانال گوش انسان، تأثیر ایرپلاگ را در فرکانس و طول&#8204;های مختلف کانال گوش مورد بررسی قرار داد.روش&#8204;ها: در این مطالعه توصیفی- تحلیلی، در یک سمت کانال گوش شبیه&#8204;سازی شده، میکروفون به عنوان دریافت&#8204; کننده صدا و در انتهای دیگر، ایرپلاگ تعبیه شد. پس از پخش صدای صورتی توسط بلندگو، میزان افت جایگذاری (Insertion loss یا IL) ایرپلاگ در فرکانس یک اکتاو و فواصل مختلف قرارگیری ایرپلاگ در کانال گوش شبیه&#8204;سازی شده (8/12، 5/17، 5/25 و 1/31 میلی&#8204;متر) بررسی و نتایج در نرم&#8204;افزار LabVIEW ثبت گردید.یافته&#8204;ها: یافته&#8204;های میزان IL ایرپلاگ در فرکانس&#8204;های یک اکتاو نشان داد که IL گوشی در فاصله 5/25 میلی&#8204;متر در مقایسه با دیگر فواصل و در فرکانس&#8204;های پایین (کمتر از 500 هرتز)، مقادیر بالاتری داشت و در این فاصله، در فرکانس حدود 4000 هرتز به بیشترین میزان رسید.نتیجه&#8204;گیری: بالاترین میزان IL برای فرکانس&#8204;های پایین در فاصله 5/25 میلی&#8204;متر حاصل شد. متوسط طول کانال گوش انسان هم 5/2 سانتی&#8204;متر است. بنابراین، بالاترین مقادیر تضعیف صدای محیط در سیستم شنوایی انسان نیز در همین طول صورت می&#8204;گیرد. با توجه به حداکثر بودن میزان IL گوشی در این فاصله و در فرکانس 4000 هرتز، ساخت گوشی حفاظتی از مواد جاذب صدای این فرکانس پیشنهاد می&#8204;شود.</abstract_fa>
	<abstract>Background: Earplug as one of the protective equipment of the auditory system has different function at different frequencies. Thus, in this study, by simulating a model of human ear canal, the effect of earplug was checked at different frequencies and different lengths of the ear canal.Methods: In this cross-sectional descriptive-analytical study, in one side of the simulated ear canal, a microphone was used as the sound receiver, and earplug was embedded in the other end of the ear canal. After playing the pink noise through the speaker, the insertion loss (IL) of earplug at one octave frequency and at different lengths of placement of earplug in simulated ear canal (12.8, 17.5, 25.5, and 31.1 mm) was examined and the results were recorded using Labview software.Findings: The result of insertion loss of earplug at one octave frequencies showed that in comparison with other distances, the insertion loss of earplug at 25.5 mm in low frequencies (below 500 Hz) was higher, and at this distance, the frequency at 4000 Hz reached the highest rate.Conclusion: The highest rate of insertion loss was achieved for low frequencies at 25.5 mm. The average length of the human ear canal is 2.5 cm; so, in human hearing system, the highest levels of environmental sound attenuation are at the this distance. Due to the maximum insertion loss of earplug at this distance and at 4000 Hz, producing protective device from absorbent substance for this frequency is suggested.</abstract>
	<keyword_fa>کانال گوش, وسایل حفاظت شنوایی, شنوایی,</keyword_fa>
	<keyword></keyword>
	<start_page>445</start_page>
	<end_page>450</end_page>
	<web_url>http://hsr.mui.ac.ir/browse.php?a_code=A-10-39-881&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Farhad </first_name>
	<middle_name></middle_name>
	<last_name>Forouharmajd</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فرهاد فروهرمجد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Assistant Professor, Department of Occupational Health Engineering, School of Public Health, Isfahan University of Medical Sciences, Isfahan, Iran</affiliation>
	<affiliation_fa>استادیار، گروه مهندسی بهداشت حرفه‌ای، دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Siamak </first_name>
	<middle_name></middle_name>
	<last_name>Pourabdian</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سیامک پورعبدیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Associate Professor, Department of Occupational Health Engineering, School of Public Health, Isfahan University of Medical Sciences,  Isfahan, Iran</affiliation>
	<affiliation_fa>دانشیار، گروه مهندسی بهداشت حرفه‌ای، دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Niloofar </first_name>
	<middle_name></middle_name>
	<last_name>Ziayi -Ghahnavieh</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نیلوفر ضیایی قهنویه</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>MSc Student , Student Research Committee AND Department of Occupational Health Engineering, School of Public Health, Isfahan University  of Medical Sciences, Isfahan, Iran</affiliation>
	<affiliation_fa>دانشجوی کارشناسی ارشد، کمیته تحقیقات دانشجویی و گروه مهندسی بهداشت حرفه‌ای، دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
