<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Health System Research</title>
<title_fa>مجله تحقیقات نظام سلامت</title_fa>
<short_title>J Health Syst Res</short_title>
<subject>Medical Sciences</subject>
<web_url>http://hsr.mui.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2783-4093</journal_id_issn>
<journal_id_issn_online>2322-5564</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.48305</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1397</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2018</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>14</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی عملکرد ماسک‌های تنفسی مورد استفاده شاغلان نسوزکاری در کنترل مواجهه با آلاینده‌های ذره‌ای در یک صنعت تولید فولاد</title_fa>
	<title>Performance Evaluation of Respiratory Masks Used by Refractory Workers in Controlling Exposure against Particulate Pollutants in a Steel Factory</title>
	<subject_fa>آموزش بهداشت و ارتقاء سلامت </subject_fa>
	<subject>education health and promotion</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>مقدمه: یکی از عوامل زیان&#8204;آور در بعضی از محیط&#8204;های کاری، گرد و غبار است. استفاده از ماسک&#8204;های تصفیه کننده هوا نمونه&#8204;ای از راه&#8204;های کاهش مواجهه در محیط پر گرد و غبار می&#8204;باشد. بنابراین، هدف از انجام مطالعه حاضر، بررسی عملکرد ماسک&#8204;های تنفسی مورد استفاده در شاغلان نسوزکاری در کنترل مواجهه با آلاینده&#8204;های ذره&#8204;ای بود.روش&#8204;ها: در این مطالعه عملکرد سه نوع ماسک در برابر آلاینده&#8204;های ذره&#8204;ای مورد ارزیابی قرار گرفت. جهت بررسی عملکرد، در حین کار فرد و به&#8204; طور همزمان غلظت آلاینده در هوای خارج ماسک و هوای داخل ماسک اندازه&#8204;گیری شد و سپس، درصد کارایی و درصد نفوذ ماسک محاسبه گردید.یافته&#8204;ها: میانگین درصد نفوذ در ماسک FFP3 بیشتر از دو نوع FFP2 و نیم صورت الاستومری با فیلتر P100 برآورد گردید. بررسی کارایی دو نوع ماسک FFP3 و FFP2 برحسب طول زمان مصرف نشان داد که طی چند ساعت اول مصرف، کارایی کاهش و سپس افزایش یافت.نتیجه&#8204;گیری: با افزایش مقاومت سطح فیلتر میزان عبور جریان هوا از فضای بین ماسک و صورت افزایش می&#8204;یابد که در نتیجه کارایی ماسک کم می&#8204;شود. بنابراین، مقاومت سطح ماسک و نفوذ هوا از فضای خالی بین صورت فرد و ماسک فاکتور اصلی در تعیین کارایی ماسک می&#8204;باشد.</abstract_fa>
	<abstract>Background: Dust is one of the harmful factors in some working environments. One of the ways to reduce exposure to dust in these environments, is to use air purifying masks. Therefore, the purpose of this study was performance evaluation of respiratory masks used by refractory workers in controlling exposure against particulate pollutants in a steel factory.Methods: The performance of three types of masks against particle contamination was evaluated in this study. To evaluate the performance, simultaneously the concentration of particles in inside and outside of the mask during the work was measured; then, the percentage of efficiency and percentage of penetration rate were calculated.Findings: The mean penetration rate percentage in the FFP3 mask was higher than FFP2 and elastomeric half-mask with a P100 filter. Performance evaluation of FFP2 and FFP3 masks based on of consumption time showed that during the first few hours of consumption, the efficiency decreased, and then increased.Conclusion: Resistance surface of filter and air penetration from free space between face and around the mask is the main factor of poor performance of the masks.</abstract>
	<keyword_fa></keyword_fa>
	<keyword></keyword>
	<start_page>107</start_page>
	<end_page>113</end_page>
	<web_url>http://hsr.mui.ac.ir/browse.php?a_code=A-10-39-892&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mansour </first_name>
	<middle_name></middle_name>
	<last_name>Zare</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>منصور زارع</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460010750</code>
	<orcid>100319475328460010750</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>MSc Student, Student Research Committee AND Department of Occupational Health Engineering, School of Health, Isfahan University of Medical Sciences, Isfahan, Iran</affiliation>
	<affiliation_fa>دانشجوی کارشناسی ارشد، کمیته تحقیقات دانشجویی و گروه بهداشت حرفه‌ای، دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Masoud </first_name>
	<middle_name></middle_name>
	<last_name>Rismanchain</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مسعود ریسمانچیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460010751</code>
	<orcid>100319475328460010751</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Department of Occupational Health Engineering, School of Health, Isfahan University of Medical Sciences, Isfahan, Iran</affiliation>
	<affiliation_fa>استادیار، گروه بهداشت حرفه‌ای، دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
